Incidences of Root Microcracks Caused by Hand and Rotary File System at Different Lengths

Keywords: Reciproc, WaveOne, One Shape, ProTaper, Microcracks

Abstract

OBJECTIVES: The present research was conducted to assess incidences of root microcracks caused by hand and rotary file system at different lengths
MATERIAL AND METHODS: This in-vitro study was undertaken to assess incidence of root microcracks caused by hand and rotary file system at different lengths In total, 100 the mandibular premolar with straight roots determined with intact, fully formed apices were taken. Samples were randomly distributed into 5 groups based on the file system used: a) Group A: Control, b) Group B: Reciproc, c) Group C: WaveOne, d) Group D: One Shape and e) Group E: ProTaper. Pearson Chi-square test was used to determine the differences between groups. The dentinal defects were expressed as percentage of samples with microcracks in each group. Level of statistical significance was set at p-value less than 0.05.
RESULTS: The chi square test was used to compare the Distribution of the number of teeth in which cracks were observed on the horizontal sections. It was found to be significant with group ProTaper showing maximum cracks at 3,6,9 mm level as compared to other file system
CONCLUSION: Nickel-titanium instruments causes cracks on the apical root surface or in the root canal wall. ProTaper causes maximum dentinal cracks as compared to other file systems

Downloads

Download data is not yet available.

Author Biographies

Suchita Sukul

MDS, Conservative Dentistry and Endodontics, Private Practitioner and Consultant Dental Surgeon

Goldy Rathee

MDS, Conservative Dentistry and Endodontics, Private Practitioner and Consultant Dental Surgeon

Parimal Anand

MDS, Periodontics and Implantology, Private Practitioner and Consultant Dental Surgeon

Sakshi Kataria

Senior Lecturer, Department of Public Health Dentistry, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana

Pratibha Taneja

Senior Lecturer, Department of Public Health Dentistry, Sudha Rustagi College of Dental Sciences and Research, Faridabad, Haryana

References

Peters OA, Peters CI. Cleaning and shaping of the root canal system. Pathways of the Pulp. 2006;9:290-357.

Siqueira Jr JF. Reaction of periradicular tissues to root canal treatment: benefits and drawbacks. Endodontic Topics. 2005 Mar;10(1):123-47.

Walton RE, Torabinejad M. Principles and practice of endodontics. 3rd Edition. Saunders Company 2002: 222

Revathi M, Rao CV, Lakshminarayanan L. Revolution in endodontic instruments-A review. Endodontology. 2001;13:43-50.

Barr ES, Kleier DJ, Barr NV. Use of nickel titanium rotary files for root canal preparation in primary teeth. Pediatr Dent. 1999;21:453- 454

Ruff CM, Kriewaldt LM, Webb CT. New Advances in Nickel-Titanium Rotary Systems. clinic update. 2013;35 (8): 1-8

Kamatham R. Quick reference guide to rotary endodontic instruments-A comprehensive. Sch. J. Dent. Sci., 2017; 4(6):276-287 ISSN 2394-4951.

Liu R, Hou BX, Wesselink PR, Wu MK, Shemesh H. The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system. Journal of endodontics. 2013 Aug 1;39(8):1054-6

Bier CA, Shemesh H, Tanomaru-Filho M, Wesselink PR, Wu MK. The ability of different nickel-titanium rotary instruments to induce dentinal damage during canal preparation. J Endod. 2009;35:236–8

Kim HC, Kim HJ, Lee CJ, Kim BM, Park JK, Versluis A. Mechanical response of nickel– titanium instruments with different cross‐sectional designs during shaping of simulated curved canals. International Endodontic Journal. 2009 Jul 1;42(7):593-602

Bergmans L, Cleynenbreugel JV, Beullens M, Wavers M, Meerbeek BV. Progressive versus constant tapered shaft design using NiTi rotary instruments. IntEndod J. 2003;36:288–95.

Bryant ST, Thompson SA, Al-Omari MAO, Dummer PMH. Shaping ability of Profilerotary nickel-titanium instruments with ISO. IntEndod J. 2005;5:256–78.

Schafer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile-Part 1. Shaping ability in simulated curved canals. IntEndod J. 2002;35:505–13.

Gernhardt CR. Oneshape- a single file NiTi system for root canal instrumentation used in continuous rotation. Endo. 2013;7(3):211–16.

Roane JB, Sabala CL, Duncanson MG Jr. The ‘balanced force’ concept for instrumentation of curved canals. J Endod. 1985;11:203–11.

Southard DW, Oswald RJ, Natkin E. Instrumentation of curved molar root canals with Roane technique. J Endod. 1987;13:479–89.

Sjogren U, Figdor D, Persson S, Sundqvist G. Influence of infection at the time of root filling on the outcome of endodontic treatment of teeth with apical periodontitis. Int Endod J 1997; 30(5):297–306.

Schilder H. Cleaning and shaping the root canal. Dent Clin Amer 1974; 18(2): 269–96.

Berg JH. Definitive diagnosis of early enamel and dentinal cracks based on microscopic evaluation. Journal of Esthetic and Restorative Dentistry. 2003 Dec;15(7):401-.

Wright Jr HM, Loushine RJ, Weller RN, Kimbrough WF, Waller J, Pashley DH. Identification of resected root-end dentinal cracks: a comparative study of transillumination and dyes. Journal of endodontics. 2004 Oct 1;30(10):712-5.

Slaton CC, Loushine RJ, Weller RN, Parker MH, Kimbrough WF, Pashley DH. Identification of resected root-end dentinal cracks: a comparative study of visual magnification. Journal of endodontics. 2003 Aug 1;29(8):519-22.

Gordon MP, Chandler NP. Electronic apex locators. International endodontic journal. 2004 Jul;37(7):425-37.

De‐Deus G, Moreira EJ, Lopes HP, Elias CN. Extended cyclic fatigue life of F2 ProTaper instruments used in reciprocating movement. International endodontic journal. 2010 Dec;43(12):1063-8.

Franco V, Fabiani C, Taschieri S, Malentacca A, Bortolin M, Del Fabbro M. Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion. Journal of endodontics. 2011 Oct 1;37(10):1398-401.

Mull JP, Manjunath V, Manjunath MK. Comparison of accuracy of two electronic apex locators in the presence of various irrigants: An in vitro study. Journal of conservative dentistry: JCD. 2012 Apr;15(2):178.

Yoldas O, Yilmaz S, Atakan G, Kuden C, Kasan Z. Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file. Journal of endodontics. 2012 Feb 1;38(2):232-5.

Çapar ID, Arslan H. A review of instrumentation kinematics of engine‐driven nickel–titanium instruments. International endodontic journal. 2016 Feb;49(2):119-35.

Gavini G, Caldeira CL, Akisue E, de Miranda Candeiro GT, Kawakami DA. Resistance to flexural fatigue of Reciproc R25 files under continuous rotation and reciprocating movement. Journal of Endodontics. 2012 May 1;38(5):684-7.

Prichard J. Rotation or reciprocation: a contemporary look at NiTi instruments?. InBritish dental journal 2012 Apr (Vol. 212, No. 7, p. 345). Nature Publishing Group.

Plotino G, Grande NM, Testarelli L, Gambarini G. Cyclic fatigue of Reciproc and WaveOne reciprocating instruments. International Endodontic Journal. 2012 Jul;45(7):614-8.

Kim HC, Kwak SW, Cheung GS, Ko DH, Chung SM, Lee W. Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion: Reciproc versus WaveOne. Journal of endodontics. 2012 Apr 1;38(4):541-4.

Ruddle CJ. Endodontic canal preparation: WaveOne single-file technique. Dent Today. 2012 Jan;31(1):124-6.

Jalali S, Eftekhar B, Paymanpour P, Yazdizadeh M, Jafarzadeh M. Effects of reciproc, mtwo and protaper instruments on formation of root fracture. Iranian endodontic journal. 2015;10(4):252.

Khoshbin E, Donyavi Z, Atibeh EA, Roshanaei G, Amani F. The Effect of Canal Preparation with Four Different Rotary Systems on Formation of Dentinal Cracks: An In Vitro Evaluation. Iranian endodontic journal. 2018;13(2):163.

Hin ES, Wu MK, Wesselink PR, Shemesh H. Effects of self-adjusting file, Mtwo, and ProTaper on the root canal wall. J Endod. 2013;39(2):262–4

Pedulla E, Grande NM, Plotino G, Gambarini G, Rapisarda E. Influence of continuous or reciprocating motion on cyclic fatigue resistance of 4 different nickel-titanium rotary instruments. J Endod. 2013;39(2):258–61

Paul A, Suvarna N, Harish SK, Nooh Khazia M. Strereomicroscopic evaluation of dentinal damage caused by k-files,protaper universal, neoniti a1 and irace files-an in vitro study.Int J Adv Res 2017;5:1719 25.

Milani AS, Froughreyhani M, Rahimi S, Jafarabadi MA, Paksefat S. The effect of root canal preparation on the development of dentin cracks. Iran Endod J. 2012;7(4):177–82

Capar ID, Altunsoy M, Arslan H, Ertas H, Aydinbelge HA. Fracture strength of roots instrumented with self-adjusting file and the ProTaper rotary systems. J Endod. 2014;40(4):551–4

Kansal R, Rajput A, Talwar S, Roongta R, Verma M. Assessment of dentinal damage during canal preparation using reciprocating and rotary files. J Endod. 2014;40(9):1443–6.

CITATION
DOI: 10.26440/IHRJ/0309.12004
Published: 2019-12-13
How to Cite
1.
Suchita Sukul, Goldy Rathee, Parimal Anand, Sakshi Kataria, Pratibha Taneja. Incidences of Root Microcracks Caused by Hand and Rotary File System at Different Lengths. IHRJ [Internet]. 2019Dec.13 [cited 2024Apr.19];3(9):283-9. Available from: https://ihrjournal.com/ihrj/article/view/4